Introduction to GUTOR 920-0077A
920-0077A Product Overview
The GUTOR 920-0077A is a high-reliability industrial modular DC charger, developed by GUTOR Electric Ltd—a Switzerland-based expert in critical power solutions under the APC Group. Specifically engineered for demanding applications in power substations, industrial plants, and renewable energy storage systems, it serves as a core power supply for battery banks, ensuring stable charging and backup power support for control systems, protection relays, and emergency equipment. A standout feature is its N+X redundant design, allowing multiple power modules to operate in parallel—if one module fails, others automatically take over without interrupting the load, achieving an availability rate of 99.99%. Equipped with advanced power factor correction (PFC) technology, it minimizes input harmonic distortion (THDi ≤5%) and maximizes energy efficiency (up to 95%), reducing operational costs and easing the burden on upstream power grids. The “hot-swap” capability of its power modules enables on-site maintenance without shutting down the entire system, while support for multiple battery types (lead-acid, NiCd, Li-ion) and wide input voltage range ensures flexible adaptation to diverse industrial environments.
920-0077A Technical Specifications
-
Product Model: 920-0077A
-
Product Type: Industrial Modular DC Charger
-
Core Functions: Battery charging (multi-type compatible), N+X redundancy control, power factor correction, hot-swap maintenance
-
Input Parameters: 1-phase/3-phase AC input; Voltage range 120-480V AC ±10%; Frequency 50/60Hz ±10%
-
Output Parameters: DC output voltage 170-297V DC (programmable); Rated output current 50A per module; Total output power up to 15kW (3 modules)
-
Charging Performance: Float voltage 100-115% (programmable); Boost voltage 100-125% (programmable); Charging time 1-24 hours (adjustable)
-
Energy Efficiency: Up to 95% at full load; Power factor ≥0.99; Input THDi ≤5%
-
Redundancy & Reliability: N+X redundant configuration; MTBF (Mean Time Between Failures) ≥200,000 hours; System availability 99.99%
-
Communication Capability: RS-485, Ethernet (RJ45); Supports Modbus RTU/TCP and IEC 61850 (for substation integration)
-
Battery Compatibility: Lead-acid (VRLA, flooded), NiCd, Li-ion; Built-in battery management system (BMS) interface
-
Protection Features: Overvoltage/overcurrent protection, short-circuit protection (up to 65kA withstand), over-temperature protection, galvanic isolation
-
Operating Environment: Temperature range -10°C to +55°C; Humidity 5-95% (non-condensing); Protection rating IP20 (cabinet-mounted)
-
Mechanical Dimensions: 600mm (W) × 1800mm (H) × 800mm (D) (3-module configuration); Net weight ~180kg; Bottom/top cable entry
-
Certifications: CE, UL, CSA, IEC 61000, ISO 9001 compliant
Recommended GUTOR Products
-
GUTOR Guma DC 220: 220V DC modular charger with integrated output breakers, compatible with 920-0077A for large-scale battery banks.
-
GUTOR PXP 40kVA: Online double-conversion UPS that pairs with 920-0077A to form a complete AC/DC backup power system.
-
GUTOR BMM-2000: Battery monitoring module that works with 920-0077A to provide real-time cell voltage and SoC data.
-
GUTOR PDW 20kVA: Modular UPS with hot-swappable modules, receiving backup power from 920-0077A-charged batteries.
-
GUTOR RMS-3000: Remote monitoring system that centralizes data from 920-0077A across multiple substation sites.
-
GUTOR REF615: Protection relay that uses stable DC power from 920-0077A for fault detection and isolation.
-
GUTOR OM-94035A: Power management module that monitors and controls 920-0077A’s charging status and redundancy mode.
-
GUTOR M30 Modular UPS: Scalable UPS platform that integrates with 920-0077A for redundant power protection in manufacturing plants.
-
GUTOR SDC1500: 150A battery charger/rectifier whose operating status is monitored and controlled by OM-94035A.
-
GUTOR BMM-2000: Battery monitoring module that works with OM-94035A to provide precise SoC and cell voltage data for large battery banks.
-
GUTOR PDU-80A: 80A power distribution unit with built-in OM-94035A integration for real-time load monitoring and overload protection.
-
GUTOR RMS-3000: Remote monitoring system that receives data from OM-94035A for centralized management of multiple power sites.
-
GUTOR ECO1005: 5kVA energy-saving UPS whose eco-mode activation is controlled by OM-94035A based on load conditions.
-
GUTOR PLC-100: Compact logic controller that supplements OM-94035A for complex power system control logic.
-
GUTOR HMI-700: 7-inch industrial touchscreen HMI that displays real-time data and allows configuration of OM-94035A.
-
GUTOR PDW1020: 20kVA modular UPS with hot-swappable modules, supporting capacity expansion for growing manufacturing needs.
-
GUTOR SDC1500: 150A battery charger/rectifier, perfectly matching 0P0581 to extend battery lifespan and charging speed.
-
GUTOR PLG-10KVA: UPS bypass transformer, isolating 0P0581 from grid interference in petrochemical control systems.
-
GUTOR WXW1030: 30kVA marine-grade UPS with anti-vibration design, suitable for shipboard navigation and communication equipment.
-
GUTOR M30 Modular UPS: Scalable platform from 5kVA to 150kVA, compatible with 0P0581 for redundant power configurations.
-
GUTOR PEW1040-240: 40kVA nuclear-grade UPS, providing fail-safe power for reactor auxiliary control systems.
-
GUTOR ECO1005: 5kVA energy-saving UPS with eco-mode, reducing power consumption for non-critical industrial loads.