Call us 24/7+86 15359021002
Welcome to Shenzhen Changxin Automation Equipment Co., Ltd

T8314 | ICS TRIPLEX | analog input module

$599.00

In stock

💥Name: Module/Controller/Touchpad/Driver/Load cell

Model: T8314

🚚Delivery time: goods in stock

3️⃣6️⃣5️⃣Warranty: 12 months

Shipping fee: Shipping fee: Please contact customer service.

📦Product packaging: The seller provides complete packaging

🌐Customs clearance fee: not included

☎️Phone/WeChat:15359021002

📧Email: LuckyXiao.909@Gmail.com

📲WhatsApp:+86 15359021002

 🆔Skype:+86 15359021002

❤️Other websites: www.szcxgk.com

(Note: The actual price is subject to the quotation.)

Easy Guide: ICS TRIPLEX T8314 Analog Input Safety Module

1. Product Overview

ICS TRIPLEX T8314 is a high-precision analog input module tailored for safety-critical industrial systems. As a star component of the T8000 series, the T8314 acts as a “reliable data collector”—it connects to various sensors (measuring temperature, pressure, flow, or level) and converts their continuous analog signals into digital data that the main controller can process. Widely used in oil & gas, chemical processing, and power generation, the T8314 ensures that critical process information is captured accurately and transmitted in real time, laying the foundation for safe and efficient operations.
 
Key advantages of the T8314:
  • Broad Sensor Compatibility: The T8314 works seamlessly with common analog sensors (4-20mA, 0-10V, thermocouples, RTDs), fitting into most existing industrial setups.
  • SIL 3 Compliance: Qualified for safety loops where equipment failure could lead to personnel harm or major property damage.
  • Superior Accuracy: Maintains tight measurement precision even in extreme temperatures, ensuring reliable data for critical decisions.
  • Built-In Protection: Features galvanic isolation and surge protection to shield against electrical interference and voltage spikes.
Practical application: In an offshore oil platform’s wellhead system, the T8314 monitors 12 temperature sensors and 8 pressure sensors. If a wellhead’s temperature rises above the safe threshold, the sensor sends an 18mA signal to the T8314. The T8314 transmits this data to the T8100 controller, which immediately shuts down the wellhead and activates an alarm—all within 3ms. Even with nearby pumps causing electrical noise, the T8314’s filtering technology keeps the signals stable, avoiding false alarms.
T8314

2. Key Technical Specifications

Specification Category
Details (T8314)
Typical Applications
Temperature/pressure monitoring, flow rate measurement, level sensing in refineries, chemical plants, offshore platforms
Safety Rating
IEC 61508 SIL 3; IEC 61511 SIL 3; Fully compatible with T8100/T9400 controllers
Channel Configuration
16 independent analog input channels; galvanically isolated (2500V AC) per channel
Supported Signal Types
4-20mA DC (load resistance ≤600Ω); 0-10V DC (input resistance ≥100kΩ); Thermocouples (J/K/T/E); RTDs (PT100/PT1000)
Performance
Accuracy: ±0.02% full scale; Update rate: 0.5ms per channel; Signal latency: <0.3ms
Diagnostic Features
Open sensor detection; Signal drift monitoring; Over/under range alerts; Self-test function (automatic daily)
Power Supply
24V DC ±20% (powered via T8000 rack backplane); Power consumption: ≤9W (full load)
Environmental Conditions
Operating temperature: -40℃–+80℃; Relative humidity: 5%–95% (no condensation); Vibration resistance: 15G (11ms)
Physical Specifications
Dimensions: 160mm×100mm×30mm (L×W×H); Weight: ~290g; Mounting: T8000 standard rack (1 slot)

3. System Integration Guide for T8314

Integrating the T8314 into your ICS TRIPLEX system is simple, even for technicians with basic experience. The module’s plug-and-play design and clear labeling reduce setup time, while following basic safety steps ensures smooth operation.

3.1 Step-by-Step Integration

  1. Safety Preparation: Implement Lockout/Tagout (LOTO) on the T8000 rack and all connected sensors. Never work on the T8314 while the system is powered—this prevents electric shock and accidental sensor damage.
  2. Mount the T8314: Insert the T8314 into an empty I/O slot of the T8000 rack, preferably close to the T8100 controller for better signal transmission. Push firmly until you hear a click, then secure the module with the provided screws to resist vibration.
  3. Wire the T8314: For 4-20mA/RTD sensors: Connect the sensor’s positive (+) lead to the T8314’s “AI+” terminal and negative (-) to “AI-“.
  4. For 0-10V/thermocouple sensors: Link the sensor’s signal (+) to “AI+” and (-) to “AI-“.
  5. Use ICS TRIPLEX-approved shielded cables. Connect the cable shield to the T8314’s ground terminal and the rack ground (ground resistance ≤1Ω) to reduce interference.
  6. Configure the T8314: Launch TRISTATION 1131 software and detect the T8314 via the rack’s backplane communication.
  7. Set signal types for each channel (e.g., Channels 1-4: PT100 for temperature; 5-8: 4-20mA for pressure).
  8. Define measurement ranges (e.g., 4mA = 0bar, 20mA = 100bar) to match your sensor specifications.
  9. Enable diagnostic features like open sensor detection to get real-time alerts for the T8314.
  10. Test the T8314: Power on the rack and confirm the T8314’s “Power OK” and “Com OK” LEDs are green.
  11. Use a signal calibrator to send a 12mA test signal to the T8314—verify the controller reads the corresponding value (e.g., 50bar).
  12. Disconnect a sensor wire—ensure the T8314 sends an “open sensor” fault alert to TRISTATION 1131.

3.2 Maintenance Tips for T8314

  • Daily Checks: Monitor the T8314’s channel LEDs (green = normal, yellow = out of range, red = fault) and controller alerts. Ensure sensor data displayed matches on-site conditions.
  • Weekly Inspections: Visually check the T8314’s wiring terminals for tightness (vibration can loosen connections) and inspect cables for frayed insulation or damage.
  • Quarterly Calibration: Use a standard signal calibrator to test each channel’s accuracy. If deviation exceeds ±0.02%, adjust the software offset or contact ICS TRIPLEX for service.
  • Fault Troubleshooting: If the T8314 shows a fault: 1) Check sensor wiring and connections. 2) Test the sensor with a multimeter. 3) Reset the T8314 via TRISTATION 1131. Replace the module if faults persist.

4. Recommended ICS TRIPLEX Related Models

To build a complete, reliable safety system with the T8314, pair it with these complementary ICS TRIPLEX products:
Model
Series
Key Features & Synergy with T8314
ICS TRIPLEX T8100
SIL 3 TMR safety controller—the “brain” that processes data from the T8314 and triggers safety actions (e.g., shutting down valves).
ICS TRIPLEX T8403C
T8000 I/O Series
8-channel analog output module. Works with the T8314—T8314 collects data, and T8403C adjusts actuators (e.g., control valves) based on controller commands.
ICS TRIPLEX T8850
T8000 I/O Series
16-channel digital I/O module. Complements the T8314 by handling emergency stops, alarms, and safety interlocks while the T8314 monitors process variables.
ICS TRIPLEX T9400
T9000 Controller Series
High-performance SIL 3 controller. Manages multiple T8314 modules for large-scale systems (e.g., refineries with 100+ sensors).
ICS TRIPLEX T7100
T7000 Gateway Series
Safety communication gateway. Enables the T8314 and controller to connect with third-party DCS (e.g., ABB AC 800M) via Profinet.
ICS TRIPLEX T8461C
T8000 I/O Series
16-channel analog output module. Expands the T8314’s system capacity—ideal for large chemical plants needing to control multiple actuators.
ICS TRIPLEX TRISTATION 1131
Software Series
Mandatory configuration tool for the T8314. Configures channels, runs diagnostics, and visualizes real-time data from the T8314.

    Customers reviews

    There are no reviews yet.

    Be the first to review “T8314 | ICS TRIPLEX | analog input module”

    Your email address will not be published. Required fields are marked *

    Search for products

    Back to Top
    Product has been added to your cart